| Dataset Title: | OMDS-ADCP data | SGDO-Données ADCP
|
| Institution: | Fisheries and Oceans Canada (Dataset ID: mpoSgdoADCP) |
| Range: | longitude = -87.3499 to -56.6195°E, latitude = 45.93898 to 64.33323°N, depth = 0.19 to 457.64m, time = 2002-10-31T10:30:00Z to 2025-10-15T16:00:00Z |
| Information: | Summary
| License
| FGDC
| ISO 19115
| Metadata
| Background
| Subset
| Data Access Form
| Files
|
Click on the map to specify a new center point.
Zoom:
|
Attributes {
s {
time {
String _CoordinateAxisType "Time";
Float64 actual_range 1.0360602e+9, 1.760544e+9;
String axis "T";
String cf_role "profile_id";
String ioos_category "Time";
String long_name "Time";
String standard_name "time";
String time_origin "01-JAN-1970 00:00:00";
String units "seconds since 1970-01-01T00:00:00Z";
}
latitude {
String _CoordinateAxisType "Lat";
Float64 _FillValue -9999.0;
Float64 actual_range 45.93898, 64.33323;
String axis "Y";
Float64 colorBarMaximum 90.0;
Float64 colorBarMinimum -90.0;
String ioos_category "Location";
String long_name "Latitude";
String standard_name "latitude";
String units "degrees_north";
}
longitude {
String _CoordinateAxisType "Lon";
Float64 _FillValue -9999.0;
Float64 actual_range -87.3499, -56.6195;
String axis "X";
Float64 colorBarMaximum 180.0;
Float64 colorBarMinimum -180.0;
String ioos_category "Location";
String long_name "Longitude";
String standard_name "longitude";
String units "degrees_east";
}
depth {
String _CoordinateAxisType "Height";
String _CoordinateZisPositive "down";
Float64 _FillValue -9999.0;
Float64 actual_range 0.19, 457.64;
String axis "Z";
Float64 colorBarMaximum 8000.0;
Float64 colorBarMinimum -8000.0;
String colorBarPalette "TopographyDepth";
String coverage_content_type "coordinate";
String generic_name "depth";
String ioos_category "Location";
String legacy_GF3_code "SDN:GF3::DEPH";
String long_name "bin depth below surface";
String positive "down";
String sdn_P02_urn "SDN:P02::MPMN";
String sdn_parameter_name "Depth below surface of the water body by acoustic doppler current profiler (ADCP) and computation from traveltime averaged from all operational beams and unknown sound velocity profile";
String sdn_parameter_urn "SDN:P01::PPSAADCP";
String sdn_uom_name "Metres";
String sdn_uom_urn "SDN:P06::ULAA";
Float64 sensor_depth 0.0;
String sensor_type "adcp";
String serial_number "11949";
String standard_name "depth";
String units "m";
}
TEMPP901 {
Float64 _FillValue -9999.0;
Float64 actual_range -7.1, 23.63;
String ancillary_variables "TEMPP901_QC";
Float64 bin_size 4.0;
Float64 colorBarMaximum 40.0;
Float64 colorBarMinimum -10.0;
String generic_name "temperature";
String legacy_GF3_code "SDN=GF3==TE90";
String long_name "temperature";
String sdn_parameter_name "Temperature of the water body";
String sdn_parameter_urn "SDN=P01==TEMPP901";
String sdn_uom_name "Celsius degree";
String sdn_uom_urn "SDN=P06==UPAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String units "degree_C";
Float64 xducer_offset_from_bottom 3.83;
}
TEMPP901_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 9;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing";
String flag_reference "BODC SeaDataNet";
Byte flag_values 0, 1, 2, 3, 4, 5, 9;
String generic_name "temperature_QC";
String legacy_GF3_code "SDN:GF3::QQQQ";
String long_name "Quality flag for TEMPP901";
String sdn_parameter_name "QC flag";
String sdn_parameter_urn "SDN:P02::ACFL";
String standard_name "quality_flag";
}
PTCHEI01 {
Float64 _FillValue -9999.0;
Float64 actual_range -47.4, 35.9;
Float64 bin_size 4.0;
String generic_name "pitch";
String legacy_GF3_code "SDN=GF3==PTCH";
String long_name "pitch";
String sdn_parameter_name "Orientation (pitch) of measurement platform by inclinometer";
String sdn_parameter_urn "SDN=P01==PTCHEI01";
String sdn_uom_name "Degrees";
String sdn_uom_urn "SDN=P06==UAAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "platform_pitch";
String units "degree";
Float64 xducer_offset_from_bottom 3.83;
}
PTCHEI01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 0;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
}
ROLLEI01 {
Float64 _FillValue -9999.0;
Float64 actual_range -74.2, 99.8;
Float64 bin_size 4.0;
String generic_name "roll";
String legacy_GF3_code "SDN=GF3==ROLL";
String long_name "roll";
String sdn_parameter_name "Orientation (roll angle) of measurement platform by inclinometer";
String sdn_parameter_urn "SDN=P01==ROLLEI01";
String sdn_uom_name "Degrees";
String sdn_uom_urn "SDN=P06==UAAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "platform_roll";
String units "degree";
Float64 xducer_offset_from_bottom 3.83;
}
ROLLEI01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 9;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
}
HEADCM01 {
Float64 _FillValue -9999.0;
Float64 actual_range -180.0, 380.5;
Float64 bin_size 4.0;
String generic_name "heading";
String legacy_GF3_code "SDN=GF3==HEAD";
String long_name "heading";
String sdn_parameter_name "Orientation (horizontal relative to true north) of measurement device (heading)";
String sdn_parameter_urn "SDN=P01==HEADCM01";
String sdn_uom_name "Degrees";
String sdn_uom_urn "SDN=P06==UAAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "platform_orientation";
String units "degree";
Float64 xducer_offset_from_bottom 3.83;
}
HEADCM01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 4;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
}
LCEWAP01 {
Float64 _FillValue -9999.0;
Float64 actual_range -99.9999, 999.9999;
String ancillary_variables "LCEWAP01_QC";
Float64 bin_size 4.0;
Float64 colorBarMaximum 0.5;
Float64 colorBarMinimum -0.5;
String generic_name "u";
String legacy_GF3_code "SDN=GF3==EWCT";
String long_name "eastward sea water velocity";
String sdn_parameter_name "Eastward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)";
String sdn_parameter_urn "SDN=P01==LCEWAP01";
String sdn_uom_name "metres per second";
String sdn_uom_urn "SDN=P06==UVAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "eastward_sea_water_velocity";
String units "m s-1";
Float64 xducer_offset_from_bottom 3.83;
}
LCEWAP01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 9;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing";
String flag_reference "BODC SeaDataNet";
Byte flag_values 0, 1, 2, 3, 4, 5, 9;
String generic_name "u_QC";
String legacy_GF3_code "SDN:GF3::QQQQ";
String long_name "Quality flag for LCEWAP01";
String sdn_parameter_name "QC flag";
String sdn_parameter_urn "SDN:P02::ACFL";
String standard_name "quality_flag";
}
LCNSAP01 {
Float64 _FillValue -9999.0;
Float64 actual_range -99.9999, 999.9999;
String ancillary_variables "LCNSAP01_QC";
Float64 bin_size 4.0;
Float64 colorBarMaximum 0.5;
Float64 colorBarMinimum -0.5;
String generic_name "v";
String legacy_GF3_code "SDN=GF3==NWCT";
String long_name "northward sea water velocity";
String sdn_parameter_name "Northward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)";
String sdn_parameter_urn "SDN=P01==LCNSAP01";
String sdn_uom_name "metres per second";
String sdn_uom_urn "SDN=P06==UVAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "northward_sea_water_velocity";
String units "m s-1";
Float64 xducer_offset_from_bottom 3.83;
}
LCNSAP01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 9;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing";
String flag_reference "BODC SeaDataNet";
Byte flag_values 0, 1, 2, 3, 4, 5, 9;
String generic_name "v_QC";
String legacy_GF3_code "SDN:GF3::QQQQ";
String long_name "Quality flag for LCNSAP01";
String sdn_parameter_name "QC flag";
String sdn_parameter_urn "SDN:P02::ACFL";
String standard_name "quality_flag";
}
LRZAAP01 {
Float64 _FillValue -9999.0;
Float64 actual_range -99.9999, 999.9999;
String ancillary_variables "LRZAAP01_QC";
Float64 bin_size 4.0;
Float64 colorBarMaximum 0.5;
Float64 colorBarMinimum -0.5;
String generic_name "w";
String legacy_GF3_code "SDN=GF3==VCSP";
String long_name "upward sea water velocity";
String sdn_parameter_name "Upward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)";
String sdn_parameter_urn "SDN=P01==LRZAAP01";
String sdn_uom_name "metres per second";
String sdn_uom_urn "SDN=P06==UVAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "upward_sea_water_velocity";
String units "m s-1";
Float64 xducer_offset_from_bottom 3.83;
}
LRZAAP01_QC {
Byte _FillValue 127;
String _Unsigned "false";
Byte actual_range 0, 9;
Float64 colorBarMaximum 10.0;
Float64 colorBarMinimum 0.0;
String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing";
String flag_reference "BODC SeaDataNet";
Byte flag_values 0, 1, 2, 3, 4, 5, 9;
String generic_name "w_QC";
String legacy_GF3_code "SDN:GF3::QQQQ";
String long_name "Quality flag for LRZAAP01";
String sdn_parameter_name "QC flag";
String sdn_parameter_urn "SDN:P02::ACFL";
String standard_name "quality_flag";
}
LERRAP01 {
Float64 _FillValue -9999.0;
Float64 actual_range -99.9999, 999.9999;
Float64 bin_size 4.0;
Float64 colorBarMaximum 0.1;
Float64 colorBarMinimum 0.0;
String generic_name "e";
String legacy_GF3_code "SDN=GF3==ERRV";
String long_name "error velocity in sea water";
String sdn_parameter_name "Current velocity error in the water body by moored acoustic doppler current profiler(ADCP)";
String sdn_parameter_urn "SDN=P01==LERRAP01";
String sdn_uom_name "metres per second";
String sdn_uom_urn "SDN=P06==UVAA";
Float64 sensor_depth 1.045;
String sensor_type "Teledyne RD Instruments Inc.";
String standard_name "error_velocity_in_sea_water";
String units "m s-1";
Float64 xducer_offset_from_bottom 3.83;
}
station {
String long_name "Station Identifier";
}
chief_scientist {
}
cruise_number {
}
id {
String cf_role "timeseries_id";
String long_name "Original filename";
}
}
NC_GLOBAL {
String cdm_data_type "TimeSeriesProfile";
String cdm_profile_variables "time";
String cdm_timeseries_variables "id";
String comment "Data combined from archived files";
String Conventions "CF-1.10, COARDS,tomcat/src/content/erddap/fragments/prod/mpoSgdoADCP.xml ACDD-1.3, NCCSV-1.2";
String coord_system "earth";
String country_code "Ca";
String country_institute_code "CaIML";
String creator_name "Institut Maurice-Lamontagne, Department of Fisheries and oceans Canada";
String creator_type "institution";
String cruise_description "'";
String data_type "madcp";
String defaultDataQuery "&time>=minTime&time<=maxTime";
Float64 Easternmost_Easting -56.6195;
String event_number "VAS";
String event_start_time "2025-05-04T19:30:00Z";
String featureType "TimeSeriesProfile";
String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing";
Byte flag_values 0, 1, 2, 3, 4, 5, 9;
String flags_reference "BODC SeaDataNet";
Float64 geospatial_lat_max 64.33323;
Float64 geospatial_lat_min 45.93898;
String geospatial_lat_units "degrees_north";
Float64 geospatial_lon_max -56.6195;
Float64 geospatial_lon_min -87.3499;
String geospatial_lon_units "degrees_east";
Float64 geospatial_vertical_max 457.64;
Float64 geospatial_vertical_min 0.19;
String geospatial_vertical_positive "down";
String geospatial_vertical_units "m";
String history
"2026-08-18T00:41:22Z (local files)
2026-08-18T00:41:22Z http://erddap.cioos.ca/tabledap/mpoSgdoADCP.das";
String infoUrl "www.dfo-mpo.gc.ca/index-fra.html";
String institution "Fisheries and Oceans Canada";
String instrument_type "ADCP";
String janus "4-Beam";
String keywords "ADCP, heading, pitch, roll, temperature, water velocity";
String keywords_fr "ADCP,cap,roulis,tangage,température,vitesse du courant";
String keywords_vocabulary "GCMD Science Keywords";
String license "Open Government Licence - Canada";
String licenseUrl "https://open.canada.ca/en/open-government-licence-canada";
Float64 magnetic_declination -17.0;
String magnetic_declination_units "degree east";
String naming_authority "BODC, SDC, CF, MEDS";
Float64 Northernmost_Northing 64.33323;
String odf_data_type "MADCP";
String organization "IML";
String orientation "down";
String ping_type "bb";
String platform "mooring";
String platform_vocabulary "https://vocab.nerc.ac.uk/collection/L06/current/";
String publisher_email "gddaiss-dmsaisb@dfo-mpo.gc.ca";
String publisher_type "institution";
String sensor_comments "The model and serial number are the same for the temperature and pressure sensors as the ADCP.";
Float64 sensor_depth 0.0;
String sourceUrl "(local files)";
Float64 Southernmost_Northing 45.93898;
String standard_name_vocabulary "CF Standard Name Table v70";
String subsetVariables "station, chief_scientist, cruise_number";
String summary "Data combined from archived files";
String summary_fr "Données combinées à partir de fichiers d'archive";
Float64 time_coverage_duration 163.583;
String time_coverage_end "2025-10-15T16:00:00Z";
String time_coverage_start "2002-10-31T10:30:00Z";
String title "OMDS-ADCP data | SGDO-Données ADCP";
Float64 transmit_pulse_length_m 4.33;
Float64 Westernmost_Easting -87.3499;
}
}
Data Access Protocol (DAP)
and its
selection constraints
.
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.